Rated Excellent rating
FREE DELIVERY over £350 EX VAT
FREE PROMISE we’ll beat by 5%
Get more, save more! Quantity discounts on all products
all/applications/roof-insulation/50mm-unilin-thin-r-fr-bgm-flat-roof-board
50mm Unilin FR-BGM Flat Roof Insulation Board - thumb-image-1
50mm Unilin FR-BGM Flat Roof Insulation Board - thumb-image-2
50mm Unilin FR-BGM Flat Roof Insulation Board - image-1
50mm Unilin FR-BGM Flat Roof Insulation Board - image-2

50mm Unilin FR-BGM Flat Roof Insulation Board

Unilin/ Xtratherm
Brand: Unilin/ Xtratherm
Model: B-1505
Product Code: 957
Type: Fleece finished bitumen / glass fibre facings
Application: Partially Bonded, Torched-on, Built-up Bituminous Felt Systems
Last known price:£188.82 Inc VAT (£157.35 ex VAT)
Pack Weight: 11.52kg
Pack Length: 12000mm
Pack Width: 6000mm
Pack coverage: 7.2m2
Add to Cart
Add to Quote Cart
Estimated Delivery: 3-4 Working days View Transport Policy

We offer discounts on large quantities.

Quote by Phone
+4402039519012
Quote by Email
Fill out our request form and get an answer fromour expert sales and support team.
Description

The 50mm FR-BGM Flat Roof Insulation Board from Unilin delivers exceptional thermal performance with a polypropylene fleece exterior layer and bitumen/glass fibre working surface. The mineral glass facing on the underside provides additional durability and protection. Part of Unilin's comprehensive range of high-performance 50mm flat roof boards, this product offers complete insulation solutions for diverse flat roof applications.

50mm Unilin FR-BGM Flat Roof Board was previously known as 50mm Xtratherm FR-BGM.

Product Specification

Brand: Unilin / Xtratherm®

Model: 50mm FR/BGM

Thickness: 25mm,30mm,40mm, 50mm, 60mm, 70mm, 80mm, 100mm, 110mm, 120mm, 130mm, 140mm, 150mm

Length: 1200mm

Width: 600mm

Board Coverage: 0.72m2

Pack Coverage: 10.08 m2

Pack Quantity: 10

R-Value: 2.08m2K/W

Thermal Conductivity: 0.024W/mK

Compressive Strength: 150kPa

Dimensions: 1,200mm x 600mm x 50mm

Colour: Yellowish

Density: 32kg/m3

Material: Polyisocyanurate (PIR Insulation)

Profile: Square Edge

Inner facing: Mineral Glass

Outer facing: Bitumen/glass fibre

Shipping method: Articulated Vehicle ǀ Courier

Applications: Flat Roof

BBA Certified: Yes (No. 11/4878)

ETA Notification: Yes

Features: Thermally efficient flat roof board

About

The 50mm Unilin FR-BGM represents a key component within Unilin's extensive portfolio of high-performance flat roof boards, delivering multiple advantages for flat roof construction projects:

  1. Superior thermal efficiency: This 50mm board provides outstanding insulation properties, maintaining consistent internal building temperatures and reducing energy consumption.
  2. Bituminous roofing system compatibility: Engineered to integrate seamlessly with a comprehensive range of bituminous roofing systems, ensuring straightforward installation on existing structures.
  3. Polypropylene fleece with bitumen/glass fibre facing: The reinforced working surface enhances durability and extends the service life of the 50mm Flat Roof BGM, delivering a robust and dependable solution.
  4. Environmental Product Declaration certification: The 50mm Unilin Flat Roof Insulation Board BGM holds EPD certification from the IGBC (International Green Building Council). Contact the technical support team for comprehensive information.

Key Points:

  1. Delivers excellent thermal performance.
  2. Features polypropylene fleece finished bitumen/glass fibre facings.
  3. FR-BGM allows direct application of torch on felt to the insulation surface.
  4. Works effectively with a broad spectrum of bituminous based roofing systems.

Roof Design

The 50mm Unilin Insulation Boards are compatible with an extensive range of bitumen-based waterproofing systems. These typically comprise a BS EN 13707:2013 type 3G perforated base layer or a proprietary waterproofing system. Installation should position the fleece side upward, though full bonding represents an alternative approach. For moisture and condensation management guidance, refer to BS 8217 specifications for reinforced bitumen membranes in roofing applications.

Falls

Flat roof design must incorporate appropriate falls to prevent water pooling and ensure effective drainage.

Roof Loading

The 50mm Unilin FR/BGM boards suit roof decks with minimal foot traffic and low maintenance requirements. Where regular pedestrian access is needed, install dedicated walkways. Following roof completion, protective boarding should be laid if additional site work is anticipated, preserving the roofing system's integrity.

Roof Finish

Built-up roofing systems require finishing with a reflective protective layer such as chippings. Consult the system manufacturer for specific recommendations.

Fire Performance

Fire rating, when assessed to EN 13501-5 and BS 476 Part 3 'External Fire Exposure Roof Test', depends on the specified waterproofing system.

Vapour Control Layer

Prime decks before applying hot bitumen for vapour control layer bonding. Reference BS 8217 for application procedures. Extend the VCL beyond the insulation and seal at the parapet wall.

Info

Browse our Xtratherm stock and filter by thickness or coverage using the left-hand side options. For product suitability advice or quantity discount quotations, contact us by phone on +4402038839057, email sales@insulationbee, or use Live Chat - Lowest UK Insulation Prices.

Payment methods offered by Stripe
Payment methodPayment methodPayment methodPayment methodPayment methodPayment methodPayment method