225mm Cellcore HX S Under Slab (EPS) Anti Heave Board is engineered for placement beneath reinforced concrete floor slabs, delivering dependable protection against ground heave damage. This 225mm cordek hxs incorporates a cellular structure of Expanded Polystyrene, carefully manufactured and tested to achieve precise performance standards.
Brand: Cordek®
Model: 225mm (Grade 32/42)
Thickness: 225mm
Length: 2400mm
Width: 1200mm
Coverage: 2.88m2
Grade: 32/42
Standard Panel: 2400mm x 1200mm
Beams Widths: 2400mm x 1200mm to 300mm (in 25mm increments)
Material: (EPS Insulation) Expanded Polystyrene
Shipping method: Rigid Vehicle ǀ Courier
Applications: Reinforced concrete floor slabs
BBA Certified: Yes
Maximum depth of concrete: 1220mm
Safe load: 32 kN/m2
Shrinkage Category: Low
Plasticity Index: 40-60
Fail load: 42 kN/m2
Features: Durable ǀ 4th Generation ǀ minimize wastage
Manufacturer: 225mm Cordek Cellcore HXS®
This 225mm Cordek Cellcore HX S Grade 32/42 anti heave board acts as a protective barrier under reinforced concrete floor insulation slabs, reducing the impact of ground heave by limiting upward force transmission to your structure.
The Anti Heave Board, featuring the 225mm Cordek Cellcore HXS in Grade 32/42, is precisely calibrated for concrete depths up to 1220mm and has undergone extensive testing to guarantee consistent performance delivery.
Our standard range includes various depths and grades to suit typical soil heave scenarios and concrete thicknesses. We also supply variations for pile cap and ground beam applications, plus options with integrated insulation, permanent formwork, or passive gas venting.
The 225mm Cellcore HX S range safeguards reinforced concrete floor slabs from upward forces caused by ground heave effects.
For concrete thicknesses between 1220mm and 2000mm, further grades of Cellcore are available. For further advice please contact the InsulationBee Technical Team on 02038839057 / 02038839057.
Each 225mm Cellcore hxs grade is engineered to support a specific concrete thickness, plus an allowance for live loads of 1.5 kN/m², whilst maintaining minimal creep compression over a 16-hour cure period. This is termed the \"SAFE LOAD.\"
When the predetermined load limit is reached, the polystyrene legs of the 225mm Cordek panels will buckle and fail due to upward ground movement, referred to as the \"FAIL LOAD.\"
During design, ensure the slab, beam, or pile cap accounts for the difference between its weight and the fail load, as shown in the design examples on the following page.
Browse our Cordek range and filter by thickness or coverage on the left-hand side. To discuss product suitability for your project or request a quantity discount quotation, call us on +4402038839057, email sales@insulationbee, or use Live Chat - Lowest UK Insulation board Prices.