90mm Cellcore HX S Under Slab (EPS) Anti Heave Board is engineered for placement beneath reinforced concrete floor slabs, delivering dependable protection against ground heave effects. This 90mm cordek hxs product features a cellular Expanded Polystyrene structure, carefully manufactured and tested to deliver consistent performance.
Brand: Cordek®
Model: 90mm (Grade 13/18)
Thickness: 90mm
Length: 2400mm
Width: 1200mm
Coverage: 2.88m2
Grade: 13/18
Standard Panel: 2400mm x 1200mm
Beams Widths: 2400mm x 1200mm to 300mm (in 25mm increments)
Material: (EPS Insulation) Expanded Polystyrene
Shipping method: Rigid Vehicle ǀ Courier
Applications: Reinforced concrete floor slabs
BBA Certified: Yes
Maximum depth of concrete: 460mm
Safe load: 13 kN/m2
Shrinkage Category: Low
Plasticity Index: 10-20
Fail load: 18 kN/m2
Features: Durable ǀ 4th Generation ǀ minimize wastage
Manufacturer: 90mm Cordek Cellcore HXS®
This Grade 13/18 anti heave board functions as a protective layer beneath reinforced concrete floor insulation slabs, reducing ground heave impact by limiting upward force transmission to your structure.
The 90mm Cordek Cellcore HXS Grade 13/18 is engineered and calibrated for concrete depths up to 460mm, having undergone comprehensive testing to guarantee consistent performance delivery.
Our standard range features various depths and grades to suit typical soil heave potential and concrete depth combinations. We also supply variations for pile cap and ground beam applications, or where integrated insulation, permanent formwork, or passive gas venting is needed.
The 90mm Cellcore HX S range protects reinforced concrete floor slabs from upward forces caused by ground heave effects.

For concrete thicknesses between 1220mm and 2000mm, additional Cellcore grades are available. For further guidance, contact the InsulationBee Technical Team on 02038839057 / 02038839057.
Each 90mm Cellcore hxs grade is engineered to support a specific concrete thickness, plus an additional allowance for live loads of 1.5 kN/m², with minimal creep compression during a 16-hour curing period. This is termed the "SAFE LOAD."
When the predetermined load threshold is reached, the polystyrene legs of the 90mm Cordek panels will buckle and collapse due to underlying ground movement, referred to as the "FAIL LOAD."
During design, ensure the slab, beam, or pile cap is sized to handle the difference between its own weight and the fail load, as shown in the design examples on the following page.
Browse our Cordek range and filter by thickness or coverage on the left-hand side. To discuss product suitability for your project or request a quantity discount quotation, call +4402038839057, email sales@insulationbee or use Live Chat - Lowest UK Insulation board Prices.